TAB Quimicos International
Technical data sheetTAB-HI-01 · Rev. 1 · 2026-09-22
TAB-HI-01

Hydrate inhibitor

Prevents gas hydrate formation in high-pressure, low-temperature systems.

General

Designed to inhibit gas hydrate formation in highly pressurized systems operating at relatively low temperatures. Modifies the properties of the water present and the crystal-formation temperature in gas lines, keeping them in solution even when the thermodynamic conditions for formation are reached.

Application

Onshore and offshore installations in the North, South and Marine Regions: gas intake and compression systems, conduction lines, regulation packages.

Uses and benefits

Maintains continuity of gas intake and compression, prevents deferred production from plugging, prevents internal pipeline damage and reduces maintenance costs, shutdowns and the risk of removing hydrates.

Recommended dosage

Laboratory tests as a function of pressure, salinity, water content and system temperature. Optimized by observing line pressure or pig-run results; additional injection points where water condensation is observed.

Packaging and storage

200-liter plastic drums, 1,000-liter high-density polyethylene containers with metal cage, or stainless steel containers. Store in a cool, ventilated place, protected from direct sun and rain, with containers closed when not in use. Review the product safety data sheet.

Category
Integrity and safety
Crude range
High-pressure gas systems
Solubility
Water-soluble
Typical dosage
Per lab tests

Physicochemical properties

ParameterUnitMethodSpecification
AppearanceVisualColorless liquid
Relative density 20/4 °CASTM D12980.79 – 0.96
Kinematic viscosity at 40 °CcStASTM D4451.8 – 4.2
Flash point°CASTM D5623 min.

Certificate of analysis

Every batch is analysed against the specifications on this sheet before release and ships with its certificate of analysis (CoA) and safety data sheet (SDS).

Technical contact

Dosage, compatibility, laboratory testing and field application: info@tabquimicosintl.com · +1 (956) 708-6776

Disclaimer

The information on this sheet is given in good faith and reflects the specifications in force at the revision date. Values are product specifications unless stated as typical. Optimum dosage is determined by laboratory tests on the fluid to be treated. Field performance depends on conditions outside our control; no warranty is given beyond what the contract provides. Review the SDS before handling.

TAB Quimicos International, LLC · 6040 Surrey Ln, Brownsville, TX 78526, United States · info@tabquimicosintl.com · +1 (956) 708-6776 · www.tabquimicosintl.com Affiliate: TAB Químicos Industriales